Kontaktujte nás | Jazyk: čeština English
dc.title | Mechanical properties and temperature stability of modified polybutylene terephthalate by beta rays | en |
dc.contributor.author | Mizera, Aleš | |
dc.contributor.author | Maňas, Miroslav | |
dc.contributor.author | Maňas, David | |
dc.contributor.author | Stoklásek, Pavel | |
dc.contributor.author | Bednařík, Martin | |
dc.contributor.author | Hýlová, Lenka | |
dc.relation.ispartof | MATEC Web of Conferences 20th International Conference on Circuits, Systems, Communications and Computers (CSCC 2016) | |
dc.identifier.issn | 2261-236X Scopus Sources, Sherpa/RoMEO, JCR | |
dc.date.issued | 2016 | |
utb.relation.volume | 76 | |
dc.event.title | 20th International Conference on Circuits, Systems, Communications and Computers (CSCC) | |
dc.event.location | Corfu | |
utb.event.state-en | Greece | |
utb.event.state-cs | Řecko | |
dc.event.sdate | 2016-07-14 | |
dc.event.edate | 2016-07-17 | |
dc.type | conferenceObject | |
dc.language.iso | en | |
dc.publisher | EDP Sciences | |
dc.identifier.doi | 10.1051/matecconf/20167602031 | |
dc.relation.uri | https://www.matec-conferences.org/articles/matecconf/abs/2016/39/matecconf_cscc2016_02031/matecconf_cscc2016_02031.html | |
dc.description.abstract | The presented article deals with the research of mechanical properties before and after temperature load and temperature stability of modified polybutylene terephthalate by radiation cross-linking. The mechanical properties were measured, at the ambient temperature, by the tensile test on samples which were non-irradiated and irradiated by different doses of the beta radiation and then were temperature loaded. Results demonstrate that PBT has higher values of tensile strength with the increased irradiation dose and it has decreased elongation at break sharply. The purpose of the article is to consider to what extent the irradiation process influences the resulting mechanical properties and temperature stability. The PBT tested showed significant improvement of temperature stability after irradiation. This behaviour leads to the expansion of these materials in the automotive and electrical industry. | en |
utb.faculty | Faculty of Applied Informatics | |
dc.identifier.uri | http://hdl.handle.net/10563/1006997 | |
utb.identifier.obdid | 43876354 | |
utb.identifier.scopus | 2-s2.0-85016097796 | |
utb.identifier.wok | 000392332200044 | |
utb.source | d-wok | |
dc.date.accessioned | 2017-07-13T14:50:31Z | |
dc.date.available | 2017-07-13T14:50:31Z | |
dc.description.sponsorship | TBU in Zlin [IGA/FT/2016/010]; Ministry of Education, Youth and Sports of the Czech Republic within the National Sustainability Programme [L01303 (MSMT-7778/2014)]; European Regional Development Fund under the project CEBIATech [CZ.1.05/2.1.00/03.0089] | |
dc.description.sponsorship | ERDF, European Regional Development Fund; CZ.1.05/2.1.00/03.0089, ERDF, European Regional Development Fund | |
dc.rights | Attribution 4.0 International | |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.rights.access | openAccess | |
utb.contributor.internalauthor | Mizera, Aleš | |
utb.contributor.internalauthor | Maňas, Miroslav | |
utb.contributor.internalauthor | Maňas, David | |
utb.contributor.internalauthor | Stoklásek, Pavel | |
utb.contributor.internalauthor | Bednařík, Martin | |
utb.contributor.internalauthor | Hýlová, Lenka | |
utb.fulltext.affiliation | Ales Mizera 1,a, Miroslav Manas 1, David Manas 1, Pavel Stoklasek 1, Martin Bednarik 1 and Lenka Hylova 1 1 Tomas Bata University in Zlin, nam. T. G. Masaryka 5555, 76001 Zlin, Czech Republic a Corresponding author: mizera@fai.utb.cz | |
utb.fulltext.dates | - | |
utb.fulltext.sponsorship | This paper is supported by the internal grant of TBU in Zlin No. IGA/FT/2016/010 funded from the resources of specific university research and by the Ministry of Education, Youth and Sports of the Czech Republic within the National Sustainability Programme project No. LO1303 (MSMT-7778/2014) and also by the European Regional Development Fund under the project CEBIA-Tech No. CZ.1.05/2.1.00/03.0089. |