Kontaktujte nás | Jazyk: čeština English
dc.title | Testing of method for assessing of room thermal stability | en |
dc.contributor.author | Charvátová, Hana | |
dc.contributor.author | Zálešák, Martin | |
dc.relation.ispartof | MATEC Web of Conferences | |
dc.identifier.issn | 2261-236X Scopus Sources, Sherpa/RoMEO, JCR | |
dc.date.issued | 2017 | |
utb.relation.volume | 125 | |
dc.event.title | 21st International Conference on Circuits, Systems, Communications and Computers, CSCC 2017 | |
dc.event.location | Crete Island | |
utb.event.state-en | Greece | |
utb.event.state-cs | Řecko | |
dc.event.sdate | 2017-07-14 | |
dc.event.edate | 2017-07-17 | |
dc.type | conferenceObject | |
dc.language.iso | en | |
dc.publisher | EDP Sciences | |
dc.identifier.doi | 10.1051/matecconf/201712502035 | |
dc.relation.uri | https://www.matec-conferences.org/articles/matecconf/abs/2017/39/matecconf_cscc2017_02035/matecconf_cscc2017_02035.html | |
dc.description.abstract | The paper presents the interim results of our research on the developing methodological procedure which could be used for assessment of a thermal stability of buildings with regards to its thermal accumulative parameters. The principle of testing is based on a combination of computer simulation of cooled room model developed in COMSOL Multiphysics software and on theoretical calculations with respect to compliance with valid European and Czech technical standards used in building industry and architecture under conditions obtained by real measurement for the room to be tested. The presented example shows the effect of the heataccumulation properties of the outside wall insulation materials on the course of the cooling room for winter conditions. © The Authors, published by EDP Sciences, 2017. | en |
utb.faculty | Faculty of Applied Informatics | |
dc.identifier.uri | http://hdl.handle.net/10563/1007641 | |
utb.identifier.obdid | 43876828 | |
utb.identifier.scopus | 2-s2.0-85032874700 | |
utb.source | d-scopus | |
dc.date.accessioned | 2018-01-15T16:31:36Z | |
dc.date.available | 2018-01-15T16:31:36Z | |
dc.rights | Attribution 4.0 International | |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.rights.access | openAccess | |
utb.contributor.internalauthor | Charvátová, Hana | |
utb.contributor.internalauthor | Zálešák, Martin | |
utb.fulltext.affiliation | Hana Charvátová 1, Martin Zálešák 2 1 Tomas Bata University in Zlín, Faculty of Applied Informatics, Regional Research Centre CEBIA-Tech, nám. T. G. Masaryka 5555, 760 01 Zlín, Czech Republic 2 Tomas Bata University in Zlín, Faculty of Applied Informatics, Department of Automation and Control Engineering, nám. T. G. Masaryka 5555, 760 01 Zlín, Czech Republic * e-mail: charvatova@fai.utb.cz | |
utb.fulltext.dates | - | |
utb.scopus.affiliation | Tomas Bata University in Zlín, Faculty of Applied Informatics, Regional Research Centre CEBIA-Tech, nám. T. G. Masaryka 5555, Zlín, Czech Republic; Tomas Bata University in Zlín, Faculty of Applied Informatics, Department of Automation and Control Engineering, nám. T. G. Masaryka 5555, Zlín, Czech Republic | |
utb.fulltext.faculty | Faculty of Applied Informatics | |
utb.fulltext.faculty | Faculty of Applied Informatics |