Kontaktujte nás | Jazyk: čeština English
Název: | Discrepancies in Design Determination of Metal Injection Molded Tensile Test Specimens |
Autor: | Hausnerová, Berenika; Huba, Jakub |
Typ dokumentu: | Kapitola v odborné knize (English) |
ISBN: | 978-83-7242-765-6 |
Abstrakt: | The paper describes the discrepancies among tensile test specimens for determination of mechanical properties of Metal Injection Molding (MIM) materials. A standard used in Europe - "Sintered metal materials, excluding hardmetals - Tensile test pieces" differs form that proposed by American Metal Powder Industries Federation(MPIF) - "preparing and Evaluating Metal Injection Molded (MIM) Sintered/Heat Treated Tension Test Speciments". While American standard prefers speciments with holes in a T-bone shaped, the European speciments are flat, without holes. Cores in a mold cavity, which form the holes in test pieces are barrier for the flow front, but also the created weld line might be a critical place for powder/binder separation of the feedstock. |
Zobrazit celý záznam |