Kontaktujte nás | Jazyk: čeština English
dc.title | Correlation of shear and dielectric ion viscosity of dental resins - Influence of composition, temperature and filler content | en |
dc.contributor.author | Steinhaus, Johannes | |
dc.contributor.author | Hausnerová, Berenika | |
dc.contributor.author | Haenel, Thomas | |
dc.contributor.author | Selig, Daniela | |
dc.contributor.author | Duvenbeck, Fabian | |
dc.contributor.author | Moeginger, Bernhard | |
dc.relation.ispartof | Dental Materials | |
dc.identifier.issn | 0109-5641 Scopus Sources, Sherpa/RoMEO, JCR | |
dc.date.issued | 2016 | |
utb.relation.volume | 32 | |
utb.relation.issue | 7 | |
dc.citation.spage | 899 | |
dc.citation.epage | 907 | |
dc.type | article | |
dc.language.iso | en | |
dc.publisher | Elsevier | |
dc.identifier.doi | 10.1016/j.dental.2016.03.015 | |
dc.relation.uri | https://www.sciencedirect.com/science/article/pii/S0109564116300094 | |
dc.subject | Visible light curing resin | en |
dc.subject | Resin based composite | en |
dc.subject | Dielectric Analysis | en |
dc.subject | Ion viscosity | en |
dc.subject | Rheology | en |
dc.subject | Shear viscosity | en |
dc.subject | Filler content | en |
dc.description.abstract | Objective. Shear viscosity and ion viscosity of uncured visible light-curing (VLC) resins and resin based composites (RBC) are correlated with respect to the resin composition, temperature and filler content to check where Dielectric Analysis (DEA) investigations of VLC RBC generate similar results as viscosity measurements. Methods. Mixtures of bisphenol A glycidyl methacrylate (Bis-GMA) and triethylene glycol dimethacrylate (TEGDMA) as well as the pure resins were investigated and compared with two commercial VLC dental resins and RBCs (VOCO, Arabesk Top and Grandio). Shear viscosity data was obtained using a Haake Mars III, Thermo Scientific. Ion viscosity measurements performed by a dielectric cure analyzer (DEA 231/1 Epsilon with Mini IDEX-Sensor, Netzsch-Gerfiteb au). Results. Shear viscosity depends reciprocally on the mobility of molecules, whereas the ion viscosity also depends on the ion concentration as it is affected by both ion concentration and mixture viscosity. Except of pure TEGDMA, shear and ion viscosities depend on the resin composition qualitatively in a similar manner. Furthermore, shear and ion viscosities of the commercial VLC dental resins and composites exhibited the same temperature dependency regardless of filler content. Application of typical rheological models (Kitano and Quemada) revealed that ion viscosity measurements can be described with respect to filler contents of up to 30 vol.%. Significance. Rheological behavior of a VLC RBC can be characterized by DEA under the condition that the ion concentration is kept constant. Both methods address the same physical phenomenon- motion of molecules. The proposed relations allows for calculating the viscosity of any Bis-GMA-TEGDMA mixture on the base of the viscosities of the pure components. This study demonstrated the applicability of DEA investigations of VLC RBCs with respect to quality assurance purposes. (C) 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved. | en |
utb.faculty | University Institute | |
utb.faculty | Faculty of Technology | |
dc.identifier.uri | http://hdl.handle.net/10563/1006558 | |
utb.identifier.obdid | 43875207 | |
utb.identifier.scopus | 2-s2.0-84992303571 | |
utb.identifier.wok | 000377296400009 | |
utb.identifier.pubmed | 27130611 | |
utb.identifier.coden | DEMAE | |
utb.source | j-wok | |
dc.date.accessioned | 2016-08-09T14:03:00Z | |
dc.date.available | 2016-08-09T14:03:00Z | |
dc.description.sponsorship | Federal Republic of Germany, Ministry of Education and Research [17081X10]; Operational Program Research and Development for Innovations by the European Regional Development Fund (ERDF); national budget of Czech Republic [CZ.1.05/2.1.00/03.0111] | |
utb.ou | Centre of Polymer Systems | |
utb.contributor.internalauthor | Steinhaus, Johannes | |
utb.contributor.internalauthor | Hausnerová, Berenika | |
utb.contributor.internalauthor | Haenel, Thomas | |
utb.fulltext.affiliation | Johannes Steinhaus a,b, Berenika Hausnerova a,c∗, Thomas Haenel a,b, Daniela Selig b, Fabian Duvenbeck b, Bernhard Moeginger b a University Institute, Centre of Polymer Systems, Tomas Bata University in Zlín, Zlín, Czech Republic b Department of Natural Sciences, Bonn-Rhein-Sieg University of Applied Sciences, Rheinbach, Germany c Faculty of Technology, Department of Production Engineering, Tomas Bata University in Zlin, Zlín, Czech Republic ∗ Corresponding author at: University Institute, Centre of Polymer Systems, Tomas Bata University in Zlin, Zlín, Czech Republic. Tel.: +420 57 603 5166; fax: +420 57 603 1444. E-mail address: hausnerova@ft.utb.cz (B. Hausnerova). | |
utb.fulltext.dates | Received 25 March 2015 Received in revised form 10 July 2015 Accepted 22 March 2016 | |
utb.fulltext.faculty | University Institute | |
utb.fulltext.faculty | University Institute | |
utb.fulltext.faculty | Faculty of Technology | |
utb.fulltext.faculty | University Institute | |
utb.fulltext.ou | Centre of Polymer Systems | |
utb.fulltext.ou | Centre of Polymer Systems | |
utb.fulltext.ou | Department of Production Engineering | |
utb.fulltext.ou | Centre of Polymer Systems |