Contact Us | Language: čeština English
| dc.title | Blood coagulation and platelet adhesion on polyaniline films | en |
| dc.contributor.author | Humpolíček, Petr | |
| dc.contributor.author | Kuceková, Zdenka | |
| dc.contributor.author | Kašpárková, Věra | |
| dc.contributor.author | Pelková, Jana | |
| dc.contributor.author | Modic, Martina | |
| dc.contributor.author | Junkar, Ita | |
| dc.contributor.author | Trchová, Miroslava | |
| dc.contributor.author | Bober, Patrycja | |
| dc.contributor.author | Stejskal, Jaroslav | |
| dc.contributor.author | Lehocký, Marián | |
| dc.relation.ispartof | Colloids and Surfaces B: Biointerfaces | |
| dc.identifier.issn | 0927-7765 Scopus Sources, Sherpa/RoMEO, JCR | |
| dc.date.issued | 2015 | |
| utb.relation.volume | 133 | |
| dc.citation.spage | 278 | |
| dc.citation.epage | 285 | |
| dc.type | article | |
| dc.language.iso | en | |
| dc.publisher | Elsevier | |
| dc.identifier.doi | 10.1016/j.colsurfb.2015.06.008 | |
| dc.relation.uri | https://www.sciencedirect.com/science/article/pii/S092777651500380X | |
| dc.subject | Blood coagulation | en |
| dc.subject | Hemocompatibility | en |
| dc.subject | Platelet adhesion | en |
| dc.subject | Poly(2-acrylamido-2-methyl-1-propanesulfonic acid) | en |
| dc.subject | Polyaniline | en |
| dc.description.abstract | Polyaniline is a promising conducting polymer with still increasing application potential in biomedicine. Its surface modification can be an efficient way how to introduce desired functional groups and to control its properties while keeping the bulk characteristics of the material unchanged. The purpose of the study was to synthetize thin films of pristine conducting polyaniline hydrochloride, non-conducting polyaniline base and polyaniline modified with poly(2-acrylamido-2-methyl-1-propanesulfonic acid) (PAMPSA) and investigate chosen parameters of their hemocompatibility. The modification was performed either by introduction of PAMPSA during the synthesis or by reprotonation of polyaniline base. The polyaniline hydrochloride and polyaniline base had no impact on blood coagulation and platelet adhesion. By contrast, the polyaniline reprotonated with PAMPSA completely hindered coagulation thanks to its interaction with coagulation factors Xa, Va and IIa. The significantly lower platelets adhesion was also found on this surface. Moreover, this film maintains its conductivity at pH of 6, which is an improvement in comparison with standard polyaniline hydrochloride losing most of its conductivity at pH of 4. Polyaniline film with PAMPSA introduced during synthesis had an impact on platelet adhesion but not on coagulation. The combined conductivity, anticoagulation activity, low platelet adhesion and improved conductivity at pH closer to physiological, open up new possibilities for application of polyaniline reprotonated by PAMPSA in blood-contacting devices, such as catheters or blood vessel grafts. © 2015 Elsevier B.V.. | en |
| utb.faculty | University Institute | |
| utb.faculty | Faculty of Technology | |
| dc.identifier.uri | http://hdl.handle.net/10563/1005229 | |
| utb.identifier.rivid | RIV/70883521:28610/15:43873024!RIV16-MSM-28610___ | |
| utb.identifier.obdid | 43873444 | |
| utb.identifier.scopus | 2-s2.0-84935027104 | |
| utb.identifier.wok | 000359172600034 | |
| utb.identifier.pubmed | 26119372 | |
| utb.identifier.coden | CSBBE | |
| utb.source | j-wok | |
| dc.date.accessioned | 2015-08-14T09:25:58Z | |
| dc.date.available | 2015-08-14T09:25:58Z | |
| dc.description.sponsorship | Czech Science Foundation [13-08944S]; Ministry of Education, Youth and Sport of the Czech Republic [CZ.1.05/2.1.00/03.0111]; TBU in Zlin [IGA/FT/2014/004] | |
| dc.rights | Attribution 4.0 International | |
| dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.access | openAccess | |
| utb.ou | Centre of Polymer Systems | |
| utb.contributor.internalauthor | Humpolíček, Petr | |
| utb.contributor.internalauthor | Kuceková, Zdenka | |
| utb.contributor.internalauthor | Kašpárková, Věra | |
| utb.contributor.internalauthor | Pelková, Jana | |
| utb.contributor.internalauthor | Lehocký, Marián | |
| utb.scopus.affiliation | Humpolíček P., Centre of Polymer Systems, Tomas Bata University in Zlin, Zlin, 760 01, Czech Republic, Polymer Centre, Faculty of Technology, Tomas Bata University in Zlin, T.G.M. Sq. 5555, Zlin, 76001, Czech Republic; Kuceková Z., Centre of Polymer Systems, Tomas Bata University in Zlin, Zlin, 760 01, Czech Republic; Kašpárková V., Centre of Polymer Systems, Tomas Bata University in Zlin, Zlin, 760 01, Czech Republic, Department of Fat, Surfactant and Cosmetics Technology, Faculty of Technology, Tomas Bata University in Zlin, Zlin, Czech Republic; Pelková J., Department of Hematology, Tomas Bata Regional Hospital in Zlin, Zlin, 762 75, Czech Republic, Department of Health Care Sciences, Faculty of Humanities, Tomas Bata University in Zlin, Zlin, 760 05, Czech Republic; Modic M., Department of Surface Engineering, Plasma Laboratory, Josef Stefan Institute, Ljubljana, 1000, Slovenia; Junkar I., Department of Surface Engineering, Plasma Laboratory, Josef Stefan Institute, Ljubljana, 1000, Slovenia; Trchová M., Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, Prague 6, 162 06, Czech Republic; Bober P., Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, Prague 6, 162 06, Czech Republic; Stejskal J., Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, Prague 6, 162 06, Czech Republic; Lehocký M., Centre of Polymer Systems, Tomas Bata University in Zlin, Zlin, 760 01, Czech Republic |