TBU Publications
Repository of TBU Publications

Curing kinetics of visible light curing dental resin composites investigated by dielectric analysis (DEA) This paper is dedicated to Prof. P. Eyerer's 70th birthday.

DSpace Repository

Show simple item record


dc.title Curing kinetics of visible light curing dental resin composites investigated by dielectric analysis (DEA) This paper is dedicated to Prof. P. Eyerer's 70th birthday. en
dc.contributor.author Steinhaus, Johannes
dc.contributor.author Hausnerová, Berenika
dc.contributor.author Haenel, Thomas
dc.contributor.author Großgarten, Mandy
dc.contributor.author Möginger, Bernhard
dc.relation.ispartof Dental Materials
dc.identifier.issn 0109-5641 Scopus Sources, Sherpa/RoMEO, JCR
dc.date.issued 2014
utb.relation.volume 30
utb.relation.issue 3
dc.citation.spage 372
dc.citation.epage 380
dc.type article
dc.language.iso en
dc.publisher Elsevier, Inc. en
dc.identifier.doi 10.1016/j.dental.2013.12.013
dc.relation.uri https://www.sciencedirect.com/science/article/pii/S0109564113005253
dc.subject Curing behavior en
dc.subject Curing kinetics en
dc.subject Dental composites en
dc.subject Dielectric analysis (DEA) en
dc.subject Ion viscosity en
dc.subject Visible light curing en
dc.description.abstract During the curing process of light curing dental composites the mobility of molecules and molecule segments is reduced leading to a significant increase of the viscosity as well as the ion viscosity. Thus, the kinetics of the curing behavior of 6 different composites was derived from dielectric analysis (DEA) using especially redesigned flat sensors with interdigit comb electrodes allowing for irradiation at the top side and measuring the ion viscosity at the bottom side. As the ion viscosities of dental composites change 1-3 orders of magnitude during the curing process, DEA provides a sensitive approach to evaluate their curing behavior, especially in the phase of undisturbed chain growth. In order to determine quantitative kinetic parameters a kinetic model is presented and examined for the evaluation of the ion viscosity curves. From the obtained results it is seen that DEA might be employed in the investigation of the primary curing process, the quality assurance of ingredients as well as the control of processing stability of the light curing dental composites. © 2014 Academy of Dental Materials. en
utb.faculty University Institute
utb.faculty Faculty of Technology
dc.identifier.uri http://hdl.handle.net/10563/1003687
utb.identifier.obdid 43871757
utb.identifier.scopus 2-s2.0-84894032818
utb.identifier.wok 000331718700018
utb.identifier.coden DEMAE
utb.source j-scopus
dc.date.accessioned 2014-03-13T16:50:46Z
dc.date.available 2014-03-13T16:50:46Z
dc.description.sponsorship Federal Republic of Germany, Ministry of Education and Research; Operational Program Research and Development for Innovations; European Regional Development Fund (ERDF); national budget of Czech Republic, within the framework of project Center of Polymer Systems [CZ.1.05/2.1.00/03.0111]
dc.rights.access openAccess
utb.ou Centre of Polymer Systems
utb.contributor.internalauthor Steinhaus, Johannes
utb.contributor.internalauthor Hausnerová, Berenika
utb.contributor.internalauthor Haenel, Thomas
Find Full text

Files in this item